Rework the existing hydraheadsamsungtv into a dedicated Tizen 6.5 signage head for Samsung QM43B-T and QM55B-T, as the Samsung implementation workstream of ExperienceNet #769. The owner explicitly requested this issue and a separate tmux coding session to execute it. Prepare implementation and software validation now; no target display is available.
Prior work and reuse
Implementation direction
Deliverables and acceptance
FTI scope
Known Samsung signage candidates include 55-inch positions CC38c/d/e and portrait DT9; 43-inch Samsung versus iiyama allocation at CC23 and CC38h x2 is pending. CC38a, CC38b and DT23 are regular TVs with unknown models: do not assume this 6.5 signage client supports them. DT23 needs mouse/keyboard and existing gamepad; preserve its requirement without claiming hardware support. The live venue inventory edit remains blocked by account authorization and is outside this implementation workstream.
iiyama Android implementation is separate. It is Android 8 signage, not established as Android TV; do not modify the ongoing Quest work or build the Android client in this Samsung session.
Evidence already available
/home/claude-user/hydra-moonlight-web-stream/docs/runbooks/signage-heads.md
/home/claude-user/hydra-moonlight-web-stream/docs/testbooks/signage-heads.md
Documentation commit 42776d3. Eight existing standalone probe tests pass; no target unit tested. Full Rust CI previously failed in printf-compat 0.3.1 on current nightly; investigate separately if required. This shared workstation has only approximately 265 MB free disk: avoid local SDK installs/large builds and use existing CI/build infrastructure. Preserve other sessions' working trees.
The Tizen client now exists. It is written fresh, and the source question above is no longer blocking it.
Repository: /home/claude-user/hydraheadsamsungtv, commit 2b7016a on main, 24 files. It has NO git remote yet, so it exists only on this workstation. Creating cederikdotcom/hydraheadsamsungtv is an owner call and is the one thing needed to make this durable.
Shape chosen, which is the licence-safe one of the two offered: a packaged Tizen 6.5 web application that frames the server-rendered stream page, exactly the #26 shape. The package embeds and links no hydra-moonlight-web-stream code, so the .wgt carries no GPL-3.0 obligation. If a later measured failure forces the native GameStream or WASM route from #141, that choice reopens and the licence question comes back with it.
What the application does: generates and persists its own device_id and 256-bit device_token, claims an operator invitation (launcher URL or an on-screen form), polls its assignment every 15 s, asks the cluster to mediate a session, renews the 45 s lease with 20 s to spare, and frames the returned stream_url. It owns identity, lifecycle and recovery only. The stream page owns video, audio, touch, mouse, keyboard and gamepad.
The credential boundary is enforced on the device, not just on the server. The client speaks only the scoped signage endpoints from the hydracluster branch issue-770-signage-head and never calls GET /api/v1/heads/{id}, which can serialize sunshine_username and sunshine_password. It reads only the fields it was promised, so a credential-shaped field added to a response later is dropped before it reaches storage, the DOM or a log. A test asserts that with sunshine_password, body_token and a WireGuard key in a mock response. The device token never appears in a URL, the DOM, the overlay or a log line.
Four lifecycle rules are tested rather than hoped for: the panel releases its body as soon as it stops being displayed, because signage firmware suspends a hidden widget; it drops the picture when the network goes, because a frozen frame on a wall reads as a working experience; it stops the session when assignment_revision changes; and a backoff never delays a lease renewal, which would otherwise lose a body the panel already holds.
68 tests pass, three consecutive runs, with no dependencies and no network. That includes a sandboxed DOM test that drives the real app.js through enrollment, streaming, renewal, lease expiry, hide and offline, and a packaging test that asserts the manifest keeps the 6.5 floor and declares no wildcard network origin.
Packaging: tools/package.sh builds a store-only, fixed-timestamp .wgt with no SDK, because Tizen Studio cannot be installed on this host. Two builds of one tree are byte identical, so the artifact that is eventually signed is the artifact that was tested. The archive was also read back by an independent zip implementation to check the CRCs. It is UNSIGNED and therefore NOT installable: signing needs a Samsung distributor certificate, which is a device gate rather than a software gate.
Three things an owner should know:
This client cannot work until hydracluster PR #7 merges. The scoped signage endpoints it speaks exist only on that branch.
One real gap found while testing the revision contract: hydracluster bumps assignment_revision in SetHeadAssignment, SetDistrict, SetAllowedExperiences, Deny and invitation rotation, but a direct edit of nodes.yaml does not bump it. A panel would keep streaming the previous experience until its lease ran out. Recorded in the runbook; the existing rule against editing nodes.yaml by hand covers it operationally.
Cross-reference: #811 asks whether the WebRTC relay shares one GameStream pairing identity across heads. It was raised while answering whether a browser-class head pairs at all. The answer for this client is that it never does: the relay is the GameStream client and the credentials stop at the server. If #770 ever moves to the native route, #811's answer becomes a prerequisite.
Unchanged: all QM43B-T and QM55B-T installation, decode, touch, kiosk boot, network recovery and soak tests remain NOT RUN. Neither model is supported. #769 must not be closed on this work. The icon is a 16x16 placeholder against Samsung's 117x117 guidance, and whether a firmware update preserves localStorage is unverified, which matters because if it does not, every updated panel needs a fresh invitation and the rollout procedure changes.
Repository created and pushed: cederikdotcom/hydraheadsamsungtv (private, default branch main), first commit 2b7016a. The earlier note that the work existed only on this workstation is closed.
GitHub Actions run 38764425037 is green on a clean runner: 68 tests, the package build, and a byte-for-byte comparison of two independent builds, which proves the reproducibility belongs to the packager rather than to one machine. The unsigned .wgt is attached to that run.
That leaves exactly one owner action on the software path: merge hydracluster PR #7. On hydracluster main today, handleFleetEnrollHead accepts only an empty type, hydraheadipad and hydraheadquest, and returns HTTP 400 "unknown head type: hydraheadsamsungtv", so a Samsung panel cannot enrol. Using the legacy GET /api/v1/heads/{id} route instead is refused deliberately, because that response carries sunshine_username and sunshine_password and goal.txt requires the session to be mediated on the server with no provider credential on the device.
Hardware status is unchanged: installation, decode, touch, kiosk boot, network recovery, soak and portrait at DT9 are all NOT RUN, the package is unsigned and not installable, and neither model is supported.
hydracluster PR #7 is ready for review and green. Nothing needed pushing: the branch was already in sync with its remote, so what it needed was currency and the draft flag off.
main had moved 6 commits ahead since the branch point and touched two of the same files this branch changes, pkg/api/handlers_head.go and pkg/store/store.go, from #801 and #803. origin/main is now merged into issue-770-signage-head at d6141d4. The merge was clean with nothing to resolve, and the branch is now tested against current main instead of a four-day-old base.
Validation at d6141d4: go build, go vet and go test all clean locally, and CI green on both triggers, runs 38773544922 and 38773550057. The race evidence comes from CI because this workstation has no gcc. GitHub reports the PR MERGEABLE with a CLEAN merge state.
Not merged: that is an owner call. hydracluster releases are tag driven, so merging to main does not deploy by itself, but it is still your decision. Once it lands, the Samsung client at cederikdotcom/hydraheadsamsungtv has a server to talk to for the first time.
Hardware status unchanged: all QM43B-T and QM55B-T gates remain NOT RUN and neither model is supported.
Released both sides, and a panel can load the client tomorrow without a signed package.
hydracluster: PR #7 merged (0af52dd) and tagged v2.0.125, then v2.0.126 adds the piece that actually makes a panel work. Two facts forced it: this server sends no CORS headers anywhere, and the .wgt cannot be signed from this workstation. A browser head served from any other origin could not call the API at all. So the cluster now serves the client itself at /signage/, same origin as the signage endpoints. Release runs 38946124748 and 38958695673 are green and the release server reports 2.0.126.
The embedded copy is produced by the client packager with --cluster-url same-origin and refreshed by scripts/sync-signage-client.sh, which records the client commit in CLIENT_VERSION. The Tizen manifest is deliberately excluded so a public route does not publish the author address. Eight tests cover it, and it was also checked against the running binary over loopback: /signage redirects, the page serves with Cache-Control no-store, settings.js carries the empty clusterURL, config.xml is 404, and the API answers 401 unauthenticated on the same host.
hydraheadsamsungtv: tagged v0.1.0 with the unsigned .wgt attached to the release, plus the packager support for a served copy and the URL Launcher procedure in the runbook. 71 tests, CI green.
ONE THING TO CHECK BEFORE TOUCHING A PANEL. The live cluster was still v2.0.124 with 44.1 hours of uptime when this was written. It calls StartAutoCheck(6h, true), so it self-updates and restarts within about four hours. Verify with: curl -s https://hydracluster.experiencenet.com/health (want v2.0.126) and that /signage/ answers 200. If it has not flipped, hydracluster update --force on the cluster host is the sanctioned fix and needs an owner with SSH.
What should work tomorrow: the panel loads the page, enrols, polls its config, heartbeats, and shows its idle, offline and connecting states.
What will NOT work, and it is not the panel: an assigned experience will not stream. Re-verified today that every signage file in hydrabody is build-tagged windows && amd64 AND that no route registration mounts them, so the ownership API the neck calls does not exist on a running body. The managed relay adapter in hydraneckwebrtc PR 1 is also unreleased. The session call will answer 409 or 503 and the panel will sit on Connecting.
What is genuinely unknown and is the reason to go: panel touch, the real web engine version, whether the Return key closes the application, whether the identity survives a reboot, and whether a power cycle returns to the application. All model gates remain NOT RUN and neither model is supported.
FIRST STREAM ON A SAMSUNG PANEL. rupelmonde-castle-viewer ran from the cloud body (GCP, Sunshine 2026.914) over WireGuard, through a moonlight-web relay on the kit laptop, into a QM43B-T browser. Sunshine reported server_state Busy while it played. Separately a QM43B-T enrolled as head node-0b119406 and is online in hydracluster reporting client 0.2.0.
THE ONE PERMANENT CONSTRAINT: Tizen 6.5 is Chromium M85 and its engine rejects the WASM decoders outright, with CompileError "return count of 2 exceeds that of 1" because the modules use multi-value returns. libopenh264 and libopus can never compile on this firmware, and WebCodecs is absent too. So a browser-class head on QMB-T has exactly one usable video path: the hardware one, a WebRTC track rendered into a video element. This is an engine property rather than a setting, and it applies to the signed app as much as to the browser, because the app frames the same stream page. Any plan that assumed software decode on these panels needs revising.
Fixed in code and shipped: the opus glue was a value import evaluated on page load, so the page died before any capability check ran, which is why no setting could avoid it. hydra-moonlight-web-stream ff2dc25 makes it a type-only import with a dynamic load at use, and a getInfo that proves the module instantiates, since importing alone does not detect the fault. CI green, bundle built and deployed to the kit relay. Documented in that repo at ec1d9e5: runbook plus a pass/fail testbook table with the evidence for each line.
TOUCH IS NOT WORKING, and the cause is a default rather than the hardware. The stream page defaults touchMode to mouseRelative, so on a touch panel the cursor moves relatively instead of landing where the finger lands. It needs signageInput=absoluteMouse or touch on the stream URL, set per session from the head input mode hydracluster already records. Forced to absoluteMouse at the kit now; retest pending.
PANEL INVENTORY, read from each panel's own API (GET http://:8001/api/v2/) because DHCP reports every unit as "Samsung QMB Series" whether it is touch or not: 10.110.15.162 and .163 are QM43B-T, .161 is QM43B non-touch, three further QMB unread. All platform 22_PONTUSM_LFD, Tizen, wired, 3840x2160, developerMode 0.
SIX OBSTACLES, none of them Samsung faults, all now documented in the runbooks:
THE SIGNED APP IS BLOCKED ON A CERTIFICATE, not on code. Samsung displays reject unsigned packages even in developer mode, and a hand-zipped .wgt does not work. Signing needs tizen package -t wgt -s PROFILE with a Samsung distributor certificate bound to the panels' DUIDs, normally up to ten, so six panels fit. The owner has a Samsung developer account as of today. Next steps are collecting the six DUIDs and creating the author and distributor certificates in Certificate Manager. cederikmini is node-38f14c8b and online in the cluster, so the tooling can be installed and driven remotely; only the Samsung account sign-in needs a person.
WHY THE MANAGED PATH STILL CANNOT STREAM, re-confirmed today: hydrabody's ownership routes are unmounted, and the cluster cannot reach a relay on a venue LAN because the cluster is not on the WireGuard mesh. Verified from the cluster host: no wireguard interface, and 10.10.100.24 unreachable. So cluster-mediated signage sessions need both a mounted hydrabody and a relay the cluster can reach. Today's stream deliberately bypassed the cluster.
STILL NOT RUN: touch landing correctly (retest pending), kiosk return after a power cycle, anything above 720p30, multi-contact behaviour, soak stability, portrait operation at DT9, and anything at all on QM55B-T. Neither model is supported and #769 must not be closed on this work.
FLEET FULLY IDENTIFIED, AND BOTH TARGET MODELS ARE ON SITE. Seven Samsung panels hold leases at the mobile kit, all online. Read twice by two independent sweeps, models from UPnP and device ids from the panel API:
.152 QM43B Cc38a-laser duid uuid:a05e5489-6d5c-4458-8350-fd09340a4d67
.161 QM43B Samsung QMB Series duid uuid:04128107-6c0b-4175-9a15-5bccc4b22c23
.162 QM43B-T Samsung QMB Series duid uuid:e3a79848-64ba-47dc-9a5e-024df92509ee
.163 QM43B-T Samsung QMB Series duid uuid:673dc5fa-de30-4d63-9e17-26bfc83aa5ce
.164 QM55B-T Samsung QMB Series no duid available
.165 QM55B-T Samsung QMB Series no duid available
.166 QM55B-T Box-xrvalley no duid available
So this issue's two target models are both present: two QM43B-T and three QM55B-T, plus two non-touch QM43B. The three QM55B-T are the units that arrived as a batch with consecutive MACs, and they are the three touch screens the owner has been working at.
HOW TO IDENTIFY A PANEL THAT WILL NOT TALK: GET http://:9197/dmr is the UPnP device description. It answers on all seven, needs no authentication, and carries modelName and friendlyName. Credit to the hydratam session for finding it. That is the fallback the earlier note said was missing: GET :8001/api/v2/ gives the device id but answers on only four of seven.
TOUCH IS A PROPERTY OF THE APP SHELL, NOT THE PANEL. A capability probe in the built-in Web Browser app on .166 reports navigator.maxTouchPoints 0, with remote keys registering and a finger registering nothing. .166 is a QM55B-T, a genuine touch unit, confirmed by the owner as the panel they were using and by UPnP as the model. So the hardware is fine and that app simply delivers no touch events. This also means my earlier signageInput=absoluteMouse fix, while correct for the stream page's mode handling, cannot help in that shell: it corrects the mode once events arrive and cannot create them.
Limits, stated so nobody over-reads it: it is one measurement in one app. It shows the Web Browser app is unusable for touch; it does not show that another shell works. The same probe must run inside the signed widget before the app is known to deliver touch.
THERE IS NO URL LAUNCHER ON THIS FIRMWARE. Checked on a QM43B-T: Play via offers Custom App and MagicINFO and nothing else. With Custom App downloading packages and Samsung rejecting unsigned ones even in developer mode, the chain closes: no URL Launcher, Custom App only, package only, signed only, distributor certificate. The signed package is the only install route, and now also the only remaining candidate for touch.
THREE UUID-SHAPED VALUES, AND ONLY ONE IS THE DUID. A trap that would have bound a certificate to identifiers naming nothing. On .162: the UPnP UDN is 31d2ff0a-2038-4455-bc23-5a262c16f6d8 while device.duid is e3a79848-64ba-47dc-9a5e-024df92509ee. Different values on the same panel, confirmed on all four panels that expose both. The third candidate is whatever the About screen calls the Unique Device ID, which is still unread. Which one a Samsung distributor certificate binds is UNVERIFIED, so one About screen must be compared before a certificate is requested. Rule adopted: read modelName in the same request as duid, because half the panels that answer here are non-touch and ids collected by address alone would spend certificate slots on panels that can never use them.
WHY THE THREE QM55B-T GIVE NO DEVICE ID, unresolved but cheap to test. The four that answer on 8001 also have 8002 open; the three that do not, do not. 8001 and 1515 are open on all seven. The hydratam session proposes developer mode, citing sdb on 26101; my scan found 26101 closed on all seven, so that mechanism does not reproduce here. And there is a confound: the split falls exactly along model lines, four 43 inch answering and three 55 inch silent, so a QM43B/QM55B firmware difference fits the data equally well. Enabling developer mode on one QM55B-T and re-running the curl settles it, and would hand us the device id for the panel the work is actually wanted on.
TOOLING ADDED: an attribution probe at http://10.110.2.77/probe on the kit LAN, served by the proxy in front of the relay. It prints the requesting panel's address next to maxTouchPoints, coarse-pointer, the user-agent and live touch, pointer, mouse and key counters, and logs address and user-agent server side. The point is that a reading always carries the panel it came from: an earlier measurement nearly entered the record attached to the wrong model.
WHAT IS BLOCKED ON A PERSON AT THE PANELS: the About screen DUID of .162 compared against the value above, the model and device id of the three QM55B-T, and one developer-mode toggle on a QM55B-T.
CORRECTION to the previous comment: the developer-mode explanation for the three silent QM55B-T is WITHDRAWN, not merely unconfirmed.
It rested on sdb (port 26101) listening on the four panels that answer on 8001. That reading was an artifact of probing 56 ports concurrently with untrustworthy exit codes. A sequential re-run agrees with my own scan: 26101 is CLOSED on all seven panels. With sdb listening nowhere, there is no evidence that any panel is in developer mode, so nothing supports it as the cause.
What survives is the model line. The 8001 body and port 8002 are present on all four 43 inch units and absent on all three 55 inch units, so the likely explanation is a QM43B versus QM55B firmware difference rather than a per-panel setting.
Practical consequence: do NOT enable developer mode on a panel expecting a device id to appear. At least one developer reports the change is awkward to reverse, and the reasoning that motivated the advice is dead. The hydratam session has withdrawn the same advice with the owner.
One negative result worth recording so nobody repeats the search, checked on .166: there is no device id anywhere else on a 55 inch panel. :8080/ answers 403, :8080/api/v2/ answers 404, :9197/nservice/ returns a UPnP SOAP fault, and :9197/dmr carries only the UDN, which is confirmed to be a different value from the duid on every panel that exposes both. For the three QM55B-T the id must come from the About screen.
So the single remaining gate on the signed-app route is one About screen reading, and it needs to be read on the right panel. .162 or .163 is the panel that settles the FORMAT question, because those expose a duid over the API that the About value can be compared against. .166's About value is needed too, but as the id for the panel the work is wanted on rather than as a validation, since it has no duid to contradict it.
RETRACTION: the device ids are NOT a curl away. An earlier comment on this issue said the DUIDs could be read over HTTP. That is wrong, and the gate this work put on reading one About screen before requesting a certificate is what caught it.
The owner read the About screen on .162, the only panel that can show all three values at once:
:8001/api/v2/ device.duid uuid:e3a79848-64ba-47dc-9a5e-024df92509ee UUID
:9197/dmr uuid:31d2ff0a-2038-4455-bc23-5a262c16f6d8 UUID
About screen Unique Device ID u7cljqa4... 13 char alphanumeric
So there are three different ids in two different formats, and the HTTP API does not produce the About screen value and cannot be made to. Four ids collected by curl would have been the wrong kind of value in a certificate request.
HYPOTHESIS, not a finding: community guides, which conflict and none of which is official, say the UUID-format EMUID is what a Tizen Studio certificate binds to and that Device Manager auto-detects it, while the 13 character Unique Device ID is for Samsung SERVER registration. If that holds, both values are needed for different steps and neither substitutes for the other.
THE RULE every guide agrees on, and the one to follow: let Certificate Manager auto-fill the id from a connected device. Do not type an id in by hand. A consequence is that the three QM55B-T ids most likely come from Device Manager over sdb rather than from three About screens, so nobody should be transcribing ids off panels.
STILL OPEN, and .162 is the only panel that can answer it because it is the only one that exposes an API value and is reachable by sdb: when Device Manager attaches, does Certificate Manager auto-fill e3a79848-...? Equal means the API yields EMUIDs for the four 43 inch panels. Different means there is a fourth value and the toolchain is the only trustworthy source.
BLOCKED ON: the developer-mode dialog's Host PC IP field, which must be set to the machine running sdb. The panel accepts the TCP connection on 26101 and resets it on the first bytes until that is set, which is a refusal rather than a protocol mismatch. The kit laptop's source address on the venue LAN is 10.110.15.181, verified with ip route get rather than read off the interface, because that host also carries two aliases in the same subnet that would be refused identically.
TOUCH IS CLOSED, AND THE ANSWER IS NO. Samsung documents it. QM55B-T manual, chapter 03, "Using a touchscreen monitor (Supported models: QMB-T)", under "Connecting the touch overlay": "Touch functions are not supported in applications other than the OSD menu and administrator menu."
That chapter describes driving an EXTERNAL PC: connect the PC by DP, HDMI or HDMI-DVI, connect TOUCH OUT PC on the panel to a USB port on that PC, then calibrate on the PC. A QMB-T is a touch MONITOR for a connected computer. Its own Tizen runtime is not a touch consumer, and the Touch Control menu item governs OSD gestures and the admin menu rather than applications.
Our measurements were therefore the documented behaviour, not a defect: maxTouchPoints 0, any-pointer coarse false, and zero finger events in the built-in Web Browser AND inside the signed widget, in both the top document and the full-screen iframe, while remote keys counted normally on the same live page.
CONSEQUENCE FOR THE BRIEF, which needs saying plainly: the reason to buy a QM43B-T or QM55B-T over a plain QM43B is touch, and a Tizen signage head cannot deliver touch on these panels at any client version, with any certificate, under any shell. If any part of #770 or #769 promises touch interaction on these units, that promise cannot be kept by a Tizen application and should be amended before anything else is built against it.
WHAT THE TIZEN WORK IS STILL RIGHT FOR: kiosk behaviour, auto-start, the network allowlist, and a display with no cursor and no browser chrome. That part is delivered and proven on hardware today.
THE SUPPORTED TOUCH ROUTE IS AN EXTERNAL PLAYER: a small PC on HDMI plus the TOUCH OUT USB cable, running a normal browser. It also removes Chromium 85 from the picture, and with it the WASM multi-value failure, the absent WebCodecs and the no-cookies behaviour, since all three are properties of the panel's engine rather than of the content. The kit already has a NUC in the same subnet, and hydraheadflatscreen already exists for that shape of head. Recommend evaluating that for any touch requirement rather than extending the Tizen client.
DELIVERED TODAY, for the record:
TWO DEFECTS FIXED, both of which failed silently on hardware:
STILL NOT RUN: kiosk return after a power cycle, network recovery, soak, anything above 720p30, portrait at DT9, and whether a FIRMWARE update preserves localStorage. #769 must not be closed on this work.
TOUCH: BOTH WORKAROUNDS TESTED, BOTH FAIL. The question is now closed by measurement as well as by Samsung's documentation.
USB LOOPBACK, FAIL. A cable from TOUCH OUT PC back into the panel's own USB host port, on the theory that the touch overlay might enumerate as a pointer device the way a USB mouse does on a Samsung display. Nothing changed; the app still receives no pointer input.
SAMSUNG'S OWN WORKSPACE APP, FAIL. Workspace is the built-in remote-access app (Remote PC over RDP or VNC, screen sharing, Microsoft 365). It does not pass touch either. That is the strongest form of this finding: not even a Samsung SYSTEM application receives touch on these panels, so there is no privileged route being withheld from third-party apps. Touch goes to the OSD menu, the administrator menu, and the TOUCH OUT port. Nowhere else.
So the earlier conclusion stands without any remaining avenue: a Tizen signage head cannot have touch on QM43B-T or QM55B-T. The only supported route is an external machine on HDMI with the TOUCH OUT USB cable, which has to be a machine brought for the purpose.
CORRECTION to the previous comment, which named the kit NUC as the candidate for that: 10.110.15.177 belongs to Soulmade and is not ours to use or probe. Owner ruling. The kit VLAN is a shared workshop network, so a host answering on 10.110.15.x is not evidence that it is ours. The machines on that LAN that ARE ours are the laptop spicy-cactus-76 (10.110.15.181), the Mac test head cheeky-cactus-86 (10.110.15.178) and the seven panels.
So an external-player deployment for touch needs hardware that is not currently at the kit. That is a purchasing decision rather than an engineering one, and it should be settled before anything in #769 promises touch interaction on these units.
STOPPING POINT, 2026-10-17 evening. The kit laptop is powered off and work resumes tomorrow. Owner's direction for the next step: our signed app on ALL kit panels as a pure RECEIVER, with input parked deliberately.
THE FLEET IS EIGHT PANELS, not seven. 10.110.15.151 Tv-vr-seated appeared late and sits below the range earlier sweeps covered, so sweep .150 upward.
.151 Tv-vr-seated model not read DUID NEEDED, sdb ready
.152 Tv-vr-laser QM43B DUID NEEDED, sdb ready
.161 Tv-Riseof QM43B DUID NEEDED, About screen ONLY: refuses developer mode
.162 Tv-desk-lunarstrike QM43B-T DUID NEEDED, sdb ready
.163 Tv-desk-mendelcraft QM43B-T U7CLJQA4D65BK
.164 Tv-Box-rupelmonde QM55B-T U7CMGT6BPR3DA
.165 Tv-box-intro QM55B-T DUID NEEDED, sdb ready
.166 Tv-Box-xrvalley QM55B-T EXCMGT6BPR7VW, app installed and enrolled
"sdb ready" means developer mode on, Host PC IP set to the laptop at 10.110.15.181, and the panel restarted. The restart is part of the step: without it sdb refuses while 26101 still listens.
TOMORROW: boot the laptop, collect the four sdb DUIDs with one loop, take Tv-Riseof's from Menu/Support/About if that panel is wanted, then ONE distributor certificate regeneration covering every id, one signing, eight installs, and approve each pairing as it appears. The order is forced: adding an id later means regenerating and re-signing. The ten-device certificate limit is assumed rather than verified and should be checked in the wizard now that there are eight panels.
NOTE ON TOOLING: the laptop's exec channel wedged during the last reads, which is hydraissue #794. The node kept reporting online while hydranode stopped fetching work, visible as in_flight 0 with items queuing. DELETE on the exec queue clears the backlog but does not revive the fetch loop; a reboot does. The cause was long sweep loops with per-host sdb connect timeouts, so keep exec commands short on that host.
ALSO: hydraneck v0.18.3 released. Renaming the panels broke their classification, because the classifier matched Samsung's default series name and the OUIs 68:FC:CA and BC:45:5B were missing from its table, so Tv-vr-seated and Tv-vr-laser classified as "other". Both added with tests using the real names and MACs.
Transient state that dies with the laptop's reboot and needs re-creating only if the relay or the probe page is wanted again: the hydra-moonlight-web and hydra-sigproxy units, the 10.110.1.50 and 10.110.2.77 IP aliases, and the sdb server. The three ufw rules tagged "samsung panel test (temporary)" persist and are still on the cleanup list, along with sdb's port being reachable from the WireGuard range.
The app is on the kit as a product rather than an experiment. Client 0.2.4, tagged, installed and launched on five units across three models, all enrolled and online in venue mobile-kit, district bxl1-test-2:
| IP | Name | Model | Head |
|---|---|---|---|
| .151 | Tv-vr-seated | QM43B | node-d6599930 |
| .152 | Tv-vr-laser | QM43B | node-5e464f4f |
| .162 | Tv-desk-lunarstrike | QM43B-T | node-edb1240b |
| .163 | Tv-desk-mendelcraft | QM43B-T | node-c9c92bdd |
| .165 | Tv-box-intro | QM55B-T | node-ae4867f4 |
The owner confirmed the idle screen on the glass: the ExperienceNet mark, the word mark and the state line. Seven stale head records were deleted, including one still pointing at a terminated body.
A receiver spends most of its day with nothing assigned, and that screen is the product rather than an error state. It now carries the mark. The input probe and the diagnostic stream field moved behind one focusable button, reachable with a remote, because a display on a wall should not look like a workbench. The idle screen drifts about two per cent of the screen height over fifteen minutes, since a static bright shape on a panel rated for 24/7 leaves a ghost. Turn on Pixel Shift in each panel's OSD as well.
An open port and a failed sdb connect means the Host PC IP moved. The kit laptop came back from a reboot on a new DHCP lease while every panel still had the old address in its Host PC IP field. The panel accepts the TCP connection and resets it, so 26101 reads as open and sdb still fails. That reads as a broken panel and is not one. Fix the laptop, not eight panels.
Certificate Manager auto-fills only the panels that are CONNECTED over sdb. Four were attached when the wizard ran and three ids supplied from a list were silently dropped. Read the result back with cat SamsungCertificate/experiencenet/device-profile.xml, which lists every covered id in plain text and needs no password.
The two install errors are not alike. install failed[118, -12] ... Invalid format of certificate in signature means this panel's id is not in the certificate, and its wording points at the package, which is fine. install failed[118, -11] ... Author certificate not match means the author certificate changed since the app was installed. Read the number, not the sentence.
Regenerating the certificate replaced the author certificate too, so four already-installed panels refused the re-signed package. Recovery is uninstall, reinstall, re-pair, and the superseded head must be deleted first or approval returns a bare could not create signage head.
The owner has a Windows NUC driving a panel of this model with touch working. Two attempts here failed identically and totally: a Linux laptop and a Mac mini both saw no USB enumeration at all, on a port proven with a mouse ninety seconds earlier, with the panel confirmed displaying the PC, across two cables and two panels.
That is an electrical result, not a driver one, so "QMB-T touch is Windows only" does not follow from it. Two candidates remain open, both from Samsung's manual: there are two adjacent USB-B sockets, TOUCH OUT PC and TOUCH OUT SCREEN, and the manual says to connect the video cable before the touch cable. Every attempt hot-plugged USB into a running setup.
.165 by the kit laptop and .166 by a Mac mini, both showing a matching holding screen so a PC-fed panel does not look broken beside the widget-fed ones. Supervised on both platforms, both survive a reboot unattended, and both keep the machine awake only for as long as the screen is up.
One finding worth repeating outside this ticket: on the Linux player the desktop shell runs its own idle timers through the Wayland idle protocol, screensaver at 150 s and lock at 300 s, which a systemd inhibitor does not stop. Every measurement said the machine was awake and a screensaver would still have covered the panel.
.161 Tv-Riseof refuses developer mode, so it has no device id and no app.Runbook and testbook carry all of the above, including the recovery commands.
Owner decision needed: where is the original hydraheadsamsungtv source?
This has blocked the Tizen deliverables across four work sessions. It was only
ever asked in prose inside the plan field, so this comment makes the ask durable.
Recovery is exhausted from this workstation. 32 GitHub API probes across 8 name
variants and 4 owners all return 404. None of the 263 accessible repositories
carries a samsung or tizen name, including archived and private ones. No local
repository's history ever committed a Tizen config.xml or .wgt. The Hetzner Cloud
image route is definitively closed: zero snapshots in all three contexts, and
backups are 7 rolling daily slots enabled on only 10 of 31 servers, so no
March-era filesystem survives.
One avenue remains unsearched, and it is cheap: the Hetzner Storage Box
u645590.your-storagebox.de reachable over SSH port 23, holding
msi1060cederik-backup/Data/ at roughly 1.31 TB and 3.04 M files. hcloud cannot
see it. A read-only remote find costs nothing locally. Say the word and it gets
searched.
Please pick one:
(a) A git remote not visible from here. Give the URL and a commit.
(b) A path on another machine. Issue #26's nim_actions name the
neonim asimplementer on 2026-03-15, so which machine ran that? Issue #141 also names
a planning workstation holding ~/.claude/plans/shimmering-rolling-avalanche.md.
(c) It was never pushed. Then #26's "done" state is wrong, and writing the client
fresh needs your authorization.
If (c), there is a licensing choice attached, and it only bites in one of the two
shapes. hydra-moonlight-web-stream is GPL-3.0-or-later. A fresh client forces the
.wgt to GPL-3.0 only if the package embeds or links that browser/WASM client. The
shape #26 actually used, a fullscreen iframe onto a remotely served page, ships no
GPL code and leaves the .wgt unencumbered. Please authorize one of those two
packaging shapes along with (c).
A false lead to avoid: a convincing Tizen config.xml appears in the earlier
session logs. It belongs to the third-party repository tsoas/moonlight-webrtc-tizen,
not to Hydra. No replacement lineage has been invented.
Separately, a scope call for you. #770 has absorbed four sessions of managed
session infrastructure across hydraneckwebrtc, hydrabody, hydracluster and
hydra-moonlight-web-stream. goal.txt does authorize independent shared-stack work
while the source is blocked, so this was defensible, but it has made the critical
path longer than the legacy one, which already serves iPad and flatscreen heads.
Suggest keeping the stream input fixes and the cluster head enrollment on #770,
since both map onto this issue's own Implementation direction bullets, and moving
the hydrabody ownership subsystem, the scoped HMAC cleanup protocol, the guardian
lease work, the launch-only fork and the managed worker entry point to a new
"managed signage worker and owned-process lifecycle" issue. That lets #770 be
judged on the Tizen client.
All QM43B-T and QM55B-T hardware tests remain NOT RUN. Neither model is
supported, and #769 should not be closed on any of this work.