Found on cheeky-cactus-86 (node-8acd8c19), the Mac Mini test head, while bringing it onto the mesh.
The head's hydraguard-air tunnel never came up. hydrahead retried every ~5 minutes for as long as the log goes back:
13:14:19 WireGuard tunnel is down, restarting...
13:14:19 WireGuard tunnel restart failed: signal: killed
13:19:19 WireGuard tunnel is down, restarting...
13:19:19 WireGuard tunnel restart failed: signal: killed
signal: killed is SIGKILL. Running the binary by hand gives exit 137 with no stdout and no stderr at all.
The installed ~/.hydranode/bin/hydraguard was truncated:
| bytes | |
|---|---|
| installed on the head | 7,684,096 |
published hydraguard/production/latest/hydraguard-darwin-arm64 |
11,045,922 |
About 3.4 MB short, roughly 70% of the real file. codesign -dv reported code object is not signed at all, and codesign -s - -f refused to sign it with main executable failed strict validation, i.e. the Mach-O is malformed rather than merely unsigned.
On Apple Silicon an unsigned or malformed Mach-O cannot execute at all — the kernel SIGKILLs it before any code runs. That is why there is no error output to go on. By contrast the sibling wireguard-go in the same directory was intact and adhoc, linker-signed.
Re-downloading the same URL on the head produced exactly 11,045,922 bytes and a valid signature, and it then ran normally. So the artifact on the release server is fine; the installed copy was corrupted on the way in.
signal: killed is that something external killed it.hydrarelease/pkg/updater: download, verify checksum, backup, replace, restart). Either that verification did not run for this path, or it passed on a truncated file. Either way it did not catch a 30% short download.latest handshake: 0 and rx/tx 0/0, never once connected. The node still reported status: online to hydracluster the whole time, because hydranode talks to the public API and does not need the mesh. So a head can look healthy in the admin view while being completely unreachable over the mesh, which is the path streaming uses.codesign -dv plus a trivial --help invocation would have caught this in one step.signal: killed from a freshly updated darwin binary as a corruption signal in the log message, pointing at size and signature, so the next person does not have to find this from first principles.Before the 13:13 update the previous hydraguard binary DID run but was invoked incorrectly, printing usage and exiting 1:
13:12:28 interface utun4 created
Error: UAPI config: UAPI error: errno=-22
hydraguard tunnel up <config-file> [flags]
13:12:28 WireGuard tunnel restart failed: exit status 1
So there is also a version skew between how hydraheadflatscreen invokes hydraguard tunnel up and what the binary accepts, plus a UAPI error: errno=-22 when configuring the interface. Worth confirming that hydraheadflatscreen v2.2.5 and the current hydraguard agree on that interface.
Also seen on the same host and probably worth its own look: intermittent DNS failure (lookup hydracluster.experiencenet.com: no such host, could not resolve hydraguard.experiencenet.com) and two HTTP 401 invalid token config fetches during the update window, after which the head fell back to a cached config and kept launching the kiosk with its OLD district and venue.