Operators cannot see what a Quest head shows during a stream, and the diagnostics run is thinner than the iPad five-step.
- Screenshot captures black on Horizon OS. The streaming video surface returns a black or 0-byte frame (TODO at HydraScreenshot.kt and HydraState.kt:232). Find a capture path operators can actually use, or report the limitation honestly instead of a black frame.
- Enrich the five-step diagnostics run so it reaches iPad parity (tunnel, cluster, body reach, pairing, stream).
Done when: a remote operator gets a usable screen capture (or a clear not-supported signal), and the diagnostics run reports the full five steps.
Operator visibility DONE on master (commit 8aecccf1). Findings: the 5-step diagnostics run was already at iPad parity in HEAD. The screenshot is black ONLY on the XR path, because the frames render in the separate ALVR/WiVRn client's XR swapchain (another process), so they are uncapturable from the kiosk; PixelCopy/MediaProjection cannot reach it. Fix: detect the XR-stream case (and no-foreground) and upload a labelled JPEG card explaining why, instead of a black frame or nothing. Flat streams still capture for real. Contract + testbook updated. Needs Quest verification; not tagged yet.