HydraIssues

Experience captures about a third of a real event guide: no space requirements, setup, troubleshooting, staffing or contact
open improvement Priority: high Project: Reporter: 14 Oct 2026 08:57

Description

What prompted this

Thomas Van Bouwel sent the Laser Dance Event Guide, which is what a good maker-written hosting document actually looks like:
https://docs.google.com/document/d/14qonQPce2aY68VorKlt5nOam8upyO1kYD7EZesVSEkg/edit

I mapped every fact in it onto the Experience struct in hydraexperiencelibrary. Of about 19 distinct facts, 2 fit cleanly, 5 fit as prose with loss, and 12 have nowhere to go.

The shape of the problem

The document splits into five kinds of information, for five moments and five different readers:

  1. What the SPACE must be, before you can even place it
  2. What to BRING, weeks ahead
  3. How to SET IT UP once, on install day
  4. How to RUN ONE VISITOR, two hundred times a day
  5. What to do WHEN IT BREAKS, under pressure with a visitor waiting

We have fields for 2 and 4. Peripherals, Compute and Software cover what to bring. Instructions covers running a visitor. Nothing covers 1, 3 or 5.

What does not fit, concretely

Space requirements, and this is the expensive one. Laser Dance needs at least 3m between its two buttons; a separate room ideally, otherwise a corner or along a wall; good light but no direct sunlight; no shiny floors, with laying a carpet as the mitigation; no dark or empty walls, with posters or painters tape as the mitigation. None of that has a field.

Two reasons it matters more than the rest. It is the only class that decides WHICH ROOM an experience can go in, and hydravenues now models rooms properly, so this is the missing half of a match. And it is the class that cannot be fixed on the day: you cannot carpet a floor at 09:00 on the morning the zone opens.

Setup, done once. Clear old room scans, scan the room, and specifically do not scan adjacent booths or the hallway. Place two buttons, B to undo, reposition from room settings. This is not Instructions, which happens per visitor.

Troubleshooting. Six named failure modes with fixes: scan will not save, scan will not load, wrong scan loads, hand tracking does not engage, tracking drifts, a button ends up inside a wall. This is the only class read under time pressure, and it has nowhere to live.

Staffing. At least one staff member per demo station. It differs materially per experience: lam-gods records that a visitor does not have to touch anything, so it needs nobody, while Laser Dance needs a dedicated person. That is a rota input and today it is invisible.

Contact. thomas@laserdancegame.com, plus an in-game bug button. Experience has no contact field at all, and experience.developer is free text that does not resolve to a Developer record, so the portal cannot say who to chase. Already known, still unfiled until now.

Smaller, deliberately not proposed as fields: consumables (wet wipes between demos), accessibility (an accessible preset for reduced mobility that must be reset for the next player), brand rules for booth decoration (presskit artwork only, which the buildout partner needs), and the fact that the document marks items Required or Recommended and we have no way to express that distinction in a prose field.

Proposed

Five fields on Experience, all free text, all optional:

  • space_requirements - what the room must be, including the mitigations. The requirement side of what a venue provides.
  • staffing - how many people, and what they do.
  • setup - what to do once, before the first visitor.
  • troubleshooting - known failure modes and their fixes.
  • contact - who to reach about this experience.

And narrow the documented meaning of Instructions to per visitor only. Its current comment says "how to start it, what to say, what goes wrong and what to do about it", which is three jobs in one field. No data migration: only 2 of 22 experiences have it filled and both are already per visitor.

Complete means three repos: the fields in hydraexperiencelibrary, the form in hydramancer so a maker can actually fill them, and rendering in the hydravenues guide so they reach the floor.

Separate finding, from the same document

laser-dance has the wrong developer. The library says Realities.io. The event guide is written and signed by thomas@laserdancegame.com, and cubism in our own library already records its developer as Thomas Van Bouwel. Laser Dance is his. This was logged as an unresolved conflict between the FTI panel-copy document and the library; the event guide settles it.

Session Context

Venue
fti-experience-zone

Comments (2)

api 14 Oct 2026 08:58

Second sample, and it changes the design

The Castle Viewer manual arrived: "Castle Viewer Rupelmonde gebruikshandleiding", a 15 page PDF, 8 MB.
https://drive.google.com/file/d/11P92yJxkbK9XopIH35QRaWiGgFKYke2e/view

It is almost the opposite document to the Laser Dance guide, and the contrast is the useful part:

Laser Dance Castle Viewer
Language English Dutch
Medium text plus a video link mostly annotated screenshots
Space requirements heavy: 3m, light, floor, walls none stated
Setup scan the room, place buttons switch the TV on, get the mouse from the cabinet
Troubleshooting 6 failure modes 1, escaping to the desktop
Portable yes no, written for one room
Content inventory none yes, what is in the castle and in Rupelmonde

The finding that matters

Half of the Castle Viewer manual is venue specific, and our model has no place for it.

It opens: take the mouse and the beamer remote from the wooden cabinet to the left of the screen; reach behind the TV over the thick edge, left of the light, press the rightmost button; and the tip that the light being ON means the TV is OFF.

That is true at Rupelmonde and nowhere else. The same experience runs at FTI on CC38c, a 55 inch touch screen on a storage booth, and on CC38h, a 43 inch touch screen on an angled table. Three installations, three different answers to "how do I switch it on", one experience.

The library's design note says experience copy lives on the Experience because the same experience shows at more than one venue and should not be retyped at each. That is right for the description and for how the software works. It is wrong for how this particular installation powers on, and that is exactly the part a host needs first thing in the morning.

So the split is three ways, not one

Venue independent, on Experience: what it is, how the software works (drag to rotate, scroll to zoom, focus mode and discover mode), what is in it, software troubleshooting, space requirements, staffing, contact.

Venue specific, on the hydravenues Space: how THIS installation starts and stops, and where its peripherals live. Space has format, buildout, contact and readiness, and nothing for operating it. Proposed: one operating field.

Files, not text. Neither a text field nor a form will hold 15 pages of annotated screenshots, and it would be wrong to retype them. hydravenues already has an attachments API, /admin/venues/{id}/attachments/{scope}/{entity}. hydraexperiencelibrary has nothing equivalent, so a maker with a PDF has only briefing_url and must host it themselves. Google Drive links die when sharing changes.

Revised proposal

On Experience, the five from the description above: space_requirements, staffing, setup, troubleshooting, contact.

On hydravenues Space, one more: operating, for how this installation is switched on and off.

Also worth noting and not proposed as fields: the Castle Viewer manual is in Dutch and the library is in English, with no language recorded anywhere; and its content inventory, the treasures in the attic, the underground passage, the prison, Het Vierkant of Lood, the 17 towers, is storyteller material that is neither a description nor a hosting instruction.

api 14 Oct 2026 12:36

The split is done and tagged, hydraexperiencelibrary v0.19.0.

Experience is now a short spine plus two embedded yaml:",inline" blocks, Streaming and Hosting. Byte identical on disk and on the wire: the live 25775 byte experiences.yaml loads and writes back unchanged, asserted by TestLiveFileRoundTripsUnchanged against a copy of the real file rather than a fixture. The fixtures are written by the same struct they verify, so only the real file catches a field the struct never had.

Owner decision: label, developer and expert stay on the spine. They belong in Hosting by meaning. Moving them was rejected because the admin templates bind them by dotted path and html/template resolves at request time, so build, vet and test stay green while /admin 500s in production, and hydraheadipad decodes label as non-optional, so one guide-less experience blanks a whole iPad catalog. To revisit after FTI, with the templates and that decoder in the same change.

Both silent failure modes were reproduced before being guarded. A missing ,inline returns no error on read and zeroes the block: run against the live file it produced a copy with zero occurrences of exe_path or stream_mode, which the next Save would have written over the store. A tag used in both blocks panics inside yaml.Unmarshal at load.

internal/store had no test at all. It has eight now, including every dotted path the two admin templates use, resolved through a wrapper the way the detail page does it.

Still open from this issue: the six fields are not yet on the hydramancer studio form, so creators cannot fill them from the portal. Owner decided they are NOT public behind a share link.