api21 Nov 2026 12:25
Findings from the 2026-11-19 session on wobbly-llama-92 (node-5f8b7b59,
hostname airborne-two). The cause is NOT identified; this is recorded so the
next person does not repeat the dead ends. Context: the panel was needed in
landscape for the Visit Flanders demo on 2026-11-20 (#1204).
Confirmed
All three displays come up orient=1 (90 degrees) after every boot. \\.\DISPLAY1, the physical Samsung SECA70A on the NVIDIA output, reads 1200x1920 instead of 1920x1200. The other two are Virtual Display Driver
outputs.
The stored Windows config is LANDSCAPE. Every Rotation value under HKLM\SYSTEM\CurrentControlSet\Control\GraphicsDrivers\Configuration reads 1.
That key is 1-based (1 = 0 degrees) while DEVMODE dmDisplayOrientation is
0-based, which is an easy place to misread your own evidence. So Windows is
not restoring a saved portrait set. Something applies portrait AFTER boot,
once, and then stops.
Corrected with ChangeDisplaySettingsEx + CDS_UPDATEREGISTRY, returned 0.
A one-shot fix does NOT survive reboot, which is the tell that a writer is
still running rather than a setting being wrong.
Ruled out
LarkXR. The HKLM\...\Run entry LarkXRLauncher points at C:\Users\airborne-two-user\Downloads\LarkXR-Standlone_1761704027890\...,
which no longer exists, and no LarkXR process runs. It is a dead Run key.
Do not chase it again.
Best remaining lead, unchecked
Sunshine's output_name = {9acddf6d-43cc-576e-9aff-0c5fc80b4cc8} with dd_resolution_option = auto and dd_configuration_option = ensure_primary. Resolve that GUID. If it names the physical panel rather than a VDD, then
Sunshine rotating for the portrait mercator-talks entry (-ResX=1080 -ResY=1920) explains everything observed. Open question for whoever picks this
up: is portrait actually WANTED for the Steam Deck Mercator setup? If so, the
guard below is fighting an intended configuration.
Also unexplained: Rupelmonde auto-starts after boot with the body idle and no
session, and is reaped by the [gpu-mismatch] watchdog after about 3m29s. Two
stacked instances were seen once. Who launches it is unknown.
TWO traps that cost about an hour
Win32_VideoController LIES about rotation. It reported 1920x1200 the
entire time the desktop was 1200x1920 rotated 90 degrees. It reports the
panel's native mode and ignores rotation. On the strength of it I told the
owner "Windows is already landscape", which was wrong. The photo on this
issue is what settled it. Do not use WMI to read orientation.
Display APIs return NOTHING through the hydracluster exec channel. exec
runs as NT AUTHORITY\SYSTEM in session 0, which has no desktop, so EnumDisplayDevices and EnumDisplaySettings return empty for every device
and a screen capture produces nothing. That reads as "no displays", not as an
error. Reading OR setting orientation needs the interactive session: register
a scheduled task with New-ScheduledTaskPrincipal -LogonType Interactive
(no password needed) and send the script as a UTF-16LE base64 -EncodedCommand, which also sidesteps the quoting failures plain -Command hits through exec.
Mitigation left in place
Scheduled task HydraDisplayLandscapeGuard, modelled on crispy's HydraLocalDisplay. Runs as airborne-two-user, LogonType Interactive, RunLevel Highest, triggers at logon plus a 5-minute repeat, polls every 3
seconds, and corrects only non-VDD outputs, so Mercator's portrait VDD
streaming is untouched. It logs every correction with uptime, running processes
and body stream state.
Findings from the 2026-11-19 session on wobbly-llama-92 (node-5f8b7b59,
hostname airborne-two). The cause is NOT identified; this is recorded so the
next person does not repeat the dead ends. Context: the panel was needed in
landscape for the Visit Flanders demo on 2026-11-20 (#1204).
Confirmed
orient=1(90 degrees) after every boot.\\.\DISPLAY1, the physical SamsungSECA70Aon the NVIDIA output, reads1200x1920 instead of 1920x1200. The other two are Virtual Display Driver
outputs.
Rotationvalue underHKLM\SYSTEM\CurrentControlSet\Control\GraphicsDrivers\Configurationreads 1.That key is 1-based (1 = 0 degrees) while DEVMODE
dmDisplayOrientationis0-based, which is an easy place to misread your own evidence. So Windows is
not restoring a saved portrait set. Something applies portrait AFTER boot,
once, and then stops.
ChangeDisplaySettingsEx+CDS_UPDATEREGISTRY, returned 0.A one-shot fix does NOT survive reboot, which is the tell that a writer is
still running rather than a setting being wrong.
Ruled out
HKLM\...\RunentryLarkXRLauncherpoints atC:\Users\airborne-two-user\Downloads\LarkXR-Standlone_1761704027890\...,which no longer exists, and no LarkXR process runs. It is a dead Run key.
Do not chase it again.
Best remaining lead, unchecked
Sunshine's
output_name = {9acddf6d-43cc-576e-9aff-0c5fc80b4cc8}withdd_resolution_option = autoanddd_configuration_option = ensure_primary.Resolve that GUID. If it names the physical panel rather than a VDD, then
Sunshine rotating for the portrait
mercator-talksentry (-ResX=1080 -ResY=1920) explains everything observed. Open question for whoever picks thisup: is portrait actually WANTED for the Steam Deck Mercator setup? If so, the
guard below is fighting an intended configuration.
Also unexplained: Rupelmonde auto-starts after boot with the body
idleand nosession, and is reaped by the
[gpu-mismatch]watchdog after about 3m29s. Twostacked instances were seen once. Who launches it is unknown.
TWO traps that cost about an hour
Win32_VideoControllerLIES about rotation. It reported 1920x1200 theentire time the desktop was 1200x1920 rotated 90 degrees. It reports the
panel's native mode and ignores rotation. On the strength of it I told the
owner "Windows is already landscape", which was wrong. The photo on this
issue is what settled it. Do not use WMI to read orientation.
runs as
NT AUTHORITY\SYSTEMin session 0, which has no desktop, soEnumDisplayDevicesandEnumDisplaySettingsreturn empty for every deviceand a screen capture produces nothing. That reads as "no displays", not as an
error. Reading OR setting orientation needs the interactive session: register
a scheduled task with
New-ScheduledTaskPrincipal -LogonType Interactive(no password needed) and send the script as a UTF-16LE base64
-EncodedCommand, which also sidesteps the quoting failures plain-Commandhits through exec.Mitigation left in place
Scheduled task
HydraDisplayLandscapeGuard, modelled on crispy'sHydraLocalDisplay. Runs asairborne-two-user,LogonType Interactive,RunLevel Highest, triggers at logon plus a 5-minute repeat, polls every 3seconds, and corrects only non-VDD outputs, so Mercator's portrait VDD
streaming is untouched. It logs every correction with uptime, running processes
and body stream state.
Files:
C:\ProgramData\hydra-rotate\{guard.ps1,rotate.ps1,result.txt,guard.log}Remove with:
Unregister-ScheduledTask -TaskName HydraDisplayLandscapeGuard -Confirm:$falseWatch for it double-starting: two
guard startedlines appeared two minutesapart despite
MultipleInstances IgnoreNew.